The HBM Z6 beam load cell produced by HBM is the main component for dispensers, belt scales, as well as industrial weighing systems. In addition to its exceptional accuracy (OIML R60 accuracy class), the Z6 load cell is well suited for use in harsh operating conditions.
Various sensor modifications available (Z6FD1, Z6FC3, Z6FC4, Z6FC6)
Brief description of HBM Z6:
Type | Z6FD1 | Z6FC3 | Z6FC3MI | Z6FC4 | Z6FC6 | ||||||||
Accuracy class according to OIML R60 | D1 | C3 | C3/MI7.5 | C4 | C6 | ||||||||
Max. number of verification intervals (nLC) | 1000 | 3000 | 3000 | 4000 | 6000 | ||||||||
Maximum load (Emax) | kg | 5; 10; 20; 50; 100; 200; 500 | 10; 20; 50; 100; 200; 500 | 50; 100; 200 | 20; 50; 100; 200; 500 | 50; 100; 200 | |||||||
T | 1 | 1 | – | – | – | ||||||||
Min. verification interval, (vmin) | % of Emax | 0,0360 | 0,0090 | 0,0066 | |||||||||
Sensitivity (Cn) | mV/V | 2 | |||||||||||
Add. sensitivity deviation | % | +1; -0,1 | ±0,051 | ||||||||||
Temperature sensitivity deviation (TCD)2) | % of Cn/10K | ±0,0500 | ±0,0080 | ±0,0080 | ±0,0070 | ±0,0040 | |||||||
Temperature zero deviation (TK0) | ±0,0500 | ±0,0125 | ±0,0093 | ±0,0093 | ±0,0093 | ||||||||
Hysteresis (dhy)2) | % | ±0,0500 | ±0,0170 | ±0,0066 | ±0,0130 | ±0,0080 | |||||||
Nonlinearity(dlin)2) | ±0,0500 | ±0,0180 | ±0,0180 | ±0,0150 | ±0,0110 | ||||||||
Creep in 30 min. (dDR) | ±0,0490 | ±0,0166 | ±0,0098 | ±0,0125 | ±0,0083 | ||||||||
Input Impedance (RLC) (Black-Blue) | Ohm | 350 … 480 | |||||||||||
Output Resistance (R0) (Red-White) | 356 ± 0,2 | 356 ± 0,12 | |||||||||||
Рекоменд. напряжение питания (Uref) | V | 5 | |||||||||||
Nom. supply voltage (BU) | 0,5… 12 | ||||||||||||
Insulation resistance (Ris) | Gohm | >5 | |||||||||||
Temperature range | ºС | -30 … +40 | |||||||||||
Storage temperature range (Btl) | -50 … +85 | ||||||||||||
Limit load (EL) | % of Emax | 150 | |||||||||||
Breaking load (Ed) | ≥300 | ||||||||||||
Maximum load | kg | 5 | 10 | 20 | 50 | 100 | 200 | 500 | |||||
Permissible dynamic load (Fsrel) | % of Emax | 100 | 100 | 100 | 100 | 100 | 100 | 70 | |||||
Deflection at maximum load (snom), approx. (±15%) | mm | 0,24 | 0,3 | 0,29 | 0,27 | 0,31 | 0,39 | 0,6 | |||||
Weight (G), approx. | kg | 0,5 | 0,5 | 0,5 | 0,5 | 0,5 | 0,5 | 0,5 | |||||
Degree of protection acc. to EN 60529 (IEC 529) | IP 68 (test conditions: 1 m water column; 100 hours) | ||||||||||||
Material | |||||||||||||
Measuring body | stainless steel | ||||||||||||
Bellows | stainless steel | ||||||||||||
Cable connector | stainless steel/Viton | ||||||||||||
Cable braid | PVC |