The HBM FIT15A strain gauge is designed to convert a static and slowly changing load into a digital electrical signal.
The FIT5A digital strain gauge is as reliable as other FIT series load cells. Fast digital filter and scaling of the measured signal. Overload protection and commercial OIML R60 compliance up to 3,000 divisions ensure reliability and safety in harsh environments.
Thanks to the sealed stainless steel housing, the digital load cell can be used in the most adverse conditions (protection class IP68 / IP69K).
FIT series sensors are widely used in sorting lines, dispensers, dynamic postal scales, and filling lines.
Various advanced versions are available with control functions for diagnostics and dosing (two connecting cables).
Type | FIT5A | |||||
Accuracy class | C3 | |||||
Max. loading (emax) | kg | 5 | 10 | 20 | 30 | 50 |
Min. verification interval, standard (vmin) | g | 0,2 | 0,5 | 1 | 2 | 2 |
Max. platform size | mm | 400 х 400 | ||||
Nominal sensitivity (cn) | sign | 1 000 000 | ||||
Zero signal | 0 ± 100 000 | |||||
Temperature deviation of sensitivity (tks) in the temperature range):
+20с…+40с -10с…+20с
|
%from cn |
±0,0218
±0,0150
|
||||
Name ambient temperature | с | -10…+40 | ||||
Working temperature | -10…+50 | |||||
Storage temperature | -25…+70 | |||||
The maximum permissible load at an eccentricity of 20 mm | % from
emax
|
1000 | ||||
Weight | kg | 3 | ||||
Power supply voltage | v | +10… +30 | ||||
Power consumption | watt | <2 |