The strain gauge load cell FLINTEC RC1 is designed to convert mechanical deformation during compression into a proportional electrical signal.
It consists of an elastic element, a set of strain gauges assembled into a bridge circuit (Wheatstone bridge), and thermal compensation elements for normalizing the output signal.
Operation in harsh industrial conditions is ensured by a stainless steel housing made in the form of a bellows and a high protection class (IP68).
It is used mainly for the manufacture/modernization of automobile and carriage scales of the III accuracy class according to GOST 29329 and RM MOZM No. 76.
Features of FLINTEC RC1
Options
| Model | RC1 | |
| Symbol according to GOST 30129-96 | С1 -30/40, С3-30/40 | |
| Maximum measurement limit (MLL), kg | 25,5 / 40,8 / 61,2 / 91,2 | |
| Accuracy class according to GOST 30129-96 | С1 | С3 |
| Accuracy category according to manufacturer’s documentation | GP, C1, C3 according to OIML No. 76 | |
| Number of verification intervals, n | 1000 | 3000 |
| Operating transfer coefficient (RTC), mV/V | 2,0 ± 0,1% | |
| Combined error, % RKP | <= ± 0,03 | <= ± 0,02 |
| Operating temperature range, °C | -30…+40 (-40…+80 according to the manufacturer’s documentation) | |
| Input impedance, Ohm | 400 ± 15 | |
| Output resistance, Ohm | 351 ± 1 | |
| Insulation resistance, GOhm | >= 5 | |
| Supply voltage range, V | 5…15 | |
| Permissible overload, % NPI | 200 | |
| Destructive overload, % NPI | 300 | |
| Sensor housing material | stainless steel, 1.4548 | |
| Shielded cable, number of cores/length | 4+1 /12, 16, 18 m | |
| Protection class | IP 68 | |
| Weight, kg | <= 6 | |