The FLINTEC PC60 series shear strain gauge with SINGLE POINT technology minimizes the effect of parasitic loads and lateral displacements. The sensor is made of aluminum. Polymer filling of the measuring elements provides a high protection class (IP67).
The maximum measurement limit of the PC60 series sensors is from 30 to 750 kg. The recommended maximum size of the load receiving platform of scales that use the sensor is 600×600 mm.
Area of application: retail scales, table scales, floor scales, filling / packaging machines, weighing control systems.
Features of FLINTEC PC60
Options
Strain gauge model RS-60 | |
Symbol according to GOST 30129-96 | СЗ -20/65 |
Maximum measurement limit (MLL), kg | 30 / 50 / 100 / 200 / 300 / 500 / 750 |
Accuracy class according to GOST 30129-96 | С3 |
Number of verification intervals, n | 3000 |
Operating transfer coefficient (RTC), mV/V | 2,0 ± 10,0% |
Combined error, % RKP | <= ± 0,02 |
Operating temperature range, °C | -20…+65 |
Input impedance, Ohm | 413 ± 20 |
Output resistance, Ohm | 350 ± 25 |
Insulation resistance, GOhm | >= 5 |
Supply voltage range, V | 5…15 |
Permissible overload, % NPI | 150 |
Destructive overload, % NPI | 300 |
Sensor housing material | aluminum |
Shielded cable, number of cores/length | 6+1/3 m |
Protection class according to GOST 14254-96 | IP 67 |
Recommended maximum platform size | 600х600 mm |