Development of the KV2MD dosing weighing terminal with Modbus RTU support

Weighing controller with Modbus RTU support

Weight controller KV2MD – This is a very accurate, versatile weighing indicator that is used in a wide variety of weighing processes. It can provide an accurate and efficient solution to any task – from simple weighing to dispensing, including loading and unloading of a variety of materials. Regardless of what is used for loading or unloading: solid materials, liquid or gases, the KV2MD weight controller is capable of fully automating this process. To achieve high accuracy when dosing, the KV2MD weight controller provides a multi-stage loading/unloading algorithm with setting a threshold for switching to smooth additional loading.

The KV2MD weight controller is specially adapted for industrial weighing and, thanks to the standard Modbus RTU (Slave) communication protocol, can be easily integrated into any production line. It can be directly connected to most programmable controllers, industrial PCs and SCADA.

The KV2MD weight controller can be used in weighing systems with the number of verification divisions up to 10,000 (accuracy class III). The controller uses a 6-digit, seven-segment digital LED indicator with a green glow. The height of the indicator digits is 14 mm. The controller is equipped with a 4-key keyboard with tactile feedback. The keys are intended for basic weighing functions, as well as starting and stopping the dosing process.

Разработка дозирующего весового терминала КВ2МД

Main settings

    • Metal case dimensions 140x88x50 (WxHxD)
    • Bit capacity of analog-to-digital converter (ADC) – 24
    • 6-digit, seven-segment digital LED indicator with green light. The height of the indicator digits is 14 mm
    • Accuracy in static mode 10,000 verification divisions
    • Possibility of linearization of the load characteristics of sensors. Linearization method – 3-point piecewise linear
    • One RS232 (or RS485) communication interface for communication with a computer, printer or programmable controller
    • Supports standard Modbus RTU (Slave) protocol
    • Output of weighing results to a printer
    • Possibility of duplicating the readings of a second similar controller (communication is via the RS232/RS485 interface)
    • Three built-in relays for controlling external devices
    • Ability to operate in loadable or unloadable dispenser mode with a controlled product feed rate
    • Programmable dispensing time limitation parameter
    • Two discrete inputs for connecting external control buttons “Start” and “Stop” to control the dosing process
    • Controller supply voltage 12V or 24V DC (to be specified when ordering)
    • Calibration protection switch, access to which can be sealed